> The International Plumbing Code requires at least 21 in (533 mm) of clear floor in front of a bathroom sink, measured to any wall, fixture or door. NKBA recommends 30 in (762 mm) for comfort and describes 21 in as very tight. An accessible lavatory needs a clear floor space at least 30 in wide and 48 in deep.

## Key facts
- The International Plumbing Code requires at least 21 in (533 mm) of clearance in front of a lavatory.
- NKBA recommends 30 in (762 mm) of clear floor in front of a bathroom sink.
- The ADA Standards call for a clear floor space of 30 x 48 in at an accessible lavatory.
- The sink projection plus 21 in must fit between the wall and the nearest obstruction.
- Codes are adopted and amended locally, so confirm the figure with your inspector.

Three figures apply to the floor in front of a bathroom sink.

| Source | Clear space in front of the sink |
| --- | --- |
| International Plumbing Code, section 405.3.1 | 21 in (533 mm) minimum |
| NKBA planning recommendation | 30 in (762 mm) |
| ADA Standards, accessible lavatory | Clear floor space 30 x 48 in (762 x 1,219 mm) minimum |

## What exactly does the code say?

The International Plumbing Code says there shall be not less than a 21 in (533 mm) clearance in front of a lavatory to any wall, fixture or door. The same section requires at least 15 in (381 mm) from the center of the lavatory to a side wall or other obstruction. The locally adopted code governs.

## How far can the sink project and still leave 21 inches?

Measure from the finished wall behind the sink to the nearest thing opposite, then subtract 21 in. In a room 36 in (91 cm) wide with the sink on a side wall, the sink can project at most 15 in (38 cm). The same room cannot meet the 30 in NKBA recommendation with any sink deeper than 6 in, which is why small powder rooms work to the code minimum.

## Does a door count as an obstruction?

Yes, the code text names doors alongside walls and fixtures. How an inspector treats the swing of a door varies, so ask before you fix the layout. A door that opens outward, or a pocket door, frees the most floor in front of the sink.

## Which sinks help in a tight room?

A sink with a small projection helps most. Narrow wall-mounted stone sinks can project as little as 8 to 12 in (20 to 30 cm), and a corner sink uses floor that nothing else can use. See the [corner powder room sinks](https://www.marblesinkco.com/collections/corner-powder-room-sinks/) and the [small powder room sink guide](https://www.marblesinkco.com/guides/small-powder-room-marble-sink-guide/).

## Sources
- International Code Council: 2018 International Plumbing Code, section 405.3.1: https://www.iccsafe.org/wp-content/uploads/2018SC-PMG_P405.3.1.pdf
- Supply House Times with the NKBA: placement of bath fixtures: https://supplyht.com/articles/92491-nkba-placement-of-bath-fixtures
- U.S. Access Board: Guide to the ADA Standards, lavatories and sinks: https://www.access-board.gov/ada/guides/chapter-6-lavs-sinks