Short answer
A wall-mounted basin needs its own liquid-seal trap, set level, with a seal 2 to 4 in (51 to 102 mm) deep. Under the International Plumbing Code the trap weir sits no more than 24 in (610 mm) below the fixture outlet and the trap inlet no more than 30 in (762 mm) away horizontally. The locally adopted code governs.
- The International Plumbing Code requires each fixture to be separately trapped by a liquid-seal trap.
- A fixture trap must hold a liquid seal of at least 2 in and not more than 4 in (51 to 102 mm).
- The trap may be at most 24 in (610 mm) vertically and 30 in (762 mm) horizontally from the fixture outlet.
- S traps, bell traps, drum traps and crown-vented traps are prohibited under the International Plumbing Code.
- Pipes under an accessible lavatory must be insulated, enclosed or configured to prevent contact.
Where to buy: MarbleSinkCo carves stone sinks, tubs and tables by hand to order and sells them only through its Etsy shop, marblesinkco.etsy.com.
The trap rules below are from the International Code Council’s overview of the International Plumbing Code. The millimeter values are conversions. The plumbing code adopted locally governs, and the plumber or code official confirms the figures.
| Trap rule | International Plumbing Code figure |
|---|---|
| Trap per fixture | Each fixture separately trapped. Double trapping is not permitted |
| Liquid seal | 2 in (51 mm) minimum, 4 in (102 mm) maximum |
| Vertical distance, fixture outlet to trap weir | 24 in (610 mm) maximum |
| Horizontal distance, centerline of fixture outlet to trap inlet | 30 in (762 mm) maximum |
| Setting | Level with respect to the trap seal |
| Slip joints | Only at the trap inlet, the trap outlet and within the trap seal |
Where does the drain stub-out go for a wall-mounted basin?
In the MarbleSinkCo wall-mounted sink planning guide, the drain stub-out goes below the drain outlet of the basin and centered on it. By calculation, the underside of the basin at the drain is the rim height minus the basin height. The trap arm must enter the wall below that point, with enough tailpiece to connect. Stone does not flex, so the trap should meet the tailpiece without side load.
Which trap types are not allowed?
The International Plumbing Code prohibits S traps, bell traps, drum traps, crown-vented traps and traps that rely on moving parts to hold the seal. A trap that is not part of the fixture and depends on interior partitions for its seal is also prohibited unless it is made of approved corrosion-resistant material. Ask the code official before specifying a bottle trap. See P-traps and bottle traps.
Does an exposed trap need protection?
It does where accessibility rules apply. The ADA Standards require supply and drain pipes under an accessible lavatory to be insulated, enclosed or configured to prevent contact, as confirmed by the designer or code official against the current standard. Get the drain position and basin height in writing before the plumber sets the wall.
Read next
- What trap works under a wall-mounted stone sink: a P-trap or a bottle trap?
- What is the standard drain size for a bathroom sink, and do stone sinks use it?
- Wall-Mounted Stone Sink Installation: How to Plan It Before the Wall Is Closed
- Faucet Holes, Drains and Plumbing for Stone Sinks: What to Decide Before You Order